Sullivan-Palatek "15DVFDA" Variable Frequency Drive Air Compressor Ended
Air Compressor and Dryer - Tustin, CA
- Winning Bid : $4,550.00 USD Sold
- 57 Bid(s)
- High Bidder: m****n
Air Compressor and Dryer - Tustin, CA ( Closed #45675439 )
Custom woodworking firm in California is auctioning machinery no longer required for continuing operations. Sullivan-Palatek VFD Series Compressor, and Great Lakes Refrigerated Air Dryer.
-
Item Location
14341 Franklin Ave. Tustin CA 92780
-
Make
Sullivan-Paltek
-
Model
15DVFDA
-
Serial Number
08M003
-
Year
-
Phase
3 PHASE
-
Voltage
230 VOLT
-
Inspection Date
By appointment only, contact Thomas Aronson, [email protected]
-
Final Removal Date
See home page for details
-
Estimated Dimensions
96" L x 60" W x 72" H
-
Estimated Weight
1,500 Pounds
-
Seller Comment
Seller will disconnect and load onto buyer's flatbed truck/trailer for non-negotiable $100 loading fee. Palletizing, crating or other services may be available at an additional cost
-
Load Fee
If a load fee is established for an individual lot, that fee will include loading onto a flatbed truck (only) by the seller. Any individual lot without a load fee will be the buyer's responsibility to remove and load (at buyer’s expense).
-
page views
1158
Sullivan-Palatek "15DVFDA" Variable Frequency Drive Air Compressor
125 PSIG maximum pressure
15 HP motor
PLC with soft keys
Forklift cutouts in frame for ease of loading
Manuals
Pressure transducer motor speed control
- Factory Settings:
- Programmable digital outputs
- Digital inputs
- Programmable outputs: four relays, four transistors
- Eight programmable parameter sets with S-curves, power off function, PID process controller, electronic motor protection, internal timer. Output frequencies up to 160 Hz with output voltage stabilization; switching frequencies up to 16kHz; output phase monitoring.
- DC bus circuit connection, moto thermal sensor connection, hardware current line
- The VFD helps reduce energy. Operating at 70% capacity, the VFD consumes 10% less power than a standard compressor operating with on-off control and 20% less than a compressor with modulating control.
- The VFD has a soft start feature that maintains a low starting current. It reduces stress on the site power supply and also reduces motor wear.
- The VFD system complies with the Electro-Magnetic Compatibility standard and is UL/CSA listed.
- The VFD system is not limited to a fixed number of starts per hour.
Listed specifications were taken from manufacturer's published information and is assumed to be correct but not guaranteed. Bidder is encouraged to inspect the machine, call with questions or contact the manufacturer for more information.
The listed specifications & information were taken from the manufacturer’s published information, internet research, or seller’s description.
The specifications & information are assumed to be correct; however, in no way, guaranteed. Bidders are encouraged to inspect the machine, call with questions, or contact the manufacturer for more information.